Vent-a-Hood EUROLINE Installation Instructions - Installation Details
Page 3
L158 0311A
7" Round
Installation Details
1) Read all instructions thoroughly before beginning installation. Note: These instructions apply to standard hoods only.
Custom hoods may require additional specification consideration.
2) When installing a 14” tall Euroline wall mount range hood, it is recommended that the bottom edge of the hood be
located no more than 24” above the cooking surface. Exceeding the recommended maximum mounting height may
compromise performance.
3) Install the duct from the outside of the home to the ceiling over the exhaust outlet of the hood. Consult the connection
diagram (below) for further details on exhaust outlet placement.
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back
page of this instruction sheet.
Shown with duct cover installed (sold separately).
14” Tall Euroline Connection Diagram (30” - 48” Widths)
250 CFM K250 Blower
(Top View)
(Front View)
Model
Volts
Amps*
Hz
RPM
CFM
SP@0.0" Equivalent CFM
•
CFM
SP@0.1"
CFM
SP@0.2"
CFM
SP@0.3"
Minimum Round
Duct Size
Sones
#
K250 (Top Vent)
115
2.2
60
1550
250
375
223
220
190
7" (38 in.
2
)
7.4
* Add 0.5 amp for each halogen light. Hood is available with halogen lights (2 lights: 30" & 36", 3 lights: 42" & 48").• Because the Magic Lung
®
blower uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung
®
blower can handle cook-
ing equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently than other than other filtration systems. When comparing the Magic Lung
®
with other blower units made by other manufacturers, use the
“Equivalent CFM”.
#
Ratings in accordance with the Standard Test Code by the Energy Systems Laboratory of the Texas Engineering Experiment Station.