Vent-Axia 403368 Operating Instructions Manual - page 4
3
General Safety Information
This product is intended
for installation by a qualified service person.
Use AWG NO.16 solid conductor for wiring.
(1.2mm² for 220-240V)
Disconnect power at the
service breaker before installing or servicing.
not for household use - may case burns.
Failure to properly earth
unit could result in severe electrical shock
and/or death.
All units must be supplied
with a 3-wire service. The earth wire must
be connected to the dryer's backplate.
Important:- Read all these instructions before commencing the installation.
All wiring of this hand dryer should be in accordance with the current IEE regulations, or the appropriate
standards in your country.
This hand dryer MUST be installed by a suitably qualified person.
Ensure that the mains supply (voltage, frequency, and phase) complies with the hand dryers rating label.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or
mental capabilities, or lack of experience and knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
Installation Steps
1. Tape the installation template to the appropriate location on the mounting
surface. Drill eight (8) holes at marked locations.(fig. 1).
2. Remove template and Insert eight (8) plastic anchors (supplied) into drilled holes (fig. 2).
3. Insert eight (8) screws (supplied) to fix backplate into top plastic anchors (fig. 3).
4. Hang the dryer on the base plate (fig. 4).
5. Use key (supplied) to unlock and withdraw the tray. Screws (supplied) through
the holes at backplate bottom.
Insert the tray back and lock the security screw.
(fig. 5 ).
6. a. Connect hard wired power provided at KO location to terminal block behind cover panel (RH-bottom)
behind filter tray. Turn on circuit breaker to initiate ‘stand by- ready to operate’ status.
Connections:
A. Connect the live wire (coloured Brown) to the terminal block marked "L".
B. Connect the neutral wire (coloured Blue) to the terminal block marked "N".
C. Connect the earth wire to the terminal block marked " ". Bare earth wires should be sleeved with a
green and yellow sleeve.
b. Connect t h e power cord to initiate ‘stand by- ready to operate’ status.
7. Replace the filter access tray, being careful to not over-tighten the security screw.
8. See separate sections for owner options on heater operation and air speed adjustment.
(fig. 1)
(fig. 2)
(fig. 3)
(fig.4)