Vent-Axia LoWatt T-SERIES Installation And Operating Instructions Manual

Summary of LoWatt T-SERIES

  • Page 1

    (community design nos. 000112507-0001-0004 & 000112065-0001) read instructions in conjunction with illustrations read and save these instructions 230v/1/50hz installation, set-up and operating instructions t-series window & roof models stock ref. Nos. W ired wireless 456165a (9" ww) 456169a (9" ww) ...

  • Page 2

    2 read instructions in conjunction with the illustrations important 1. The fan must be sited and connected in accordance with current iee regulations (uk) or the appropriate standards in your country. 2. This appliance is not suitable for installation in a shower cubicle or enclosure and must be sit...

  • Page 3

    3 fan dimensions before commencing work, study the tables shown in figures c1/ c2 to ensure fan will fit in position proposed. Nb: allow a minimum of 54mm above fan casing for withdrawal of connector socket. • please note that for all roof fan installations a suitable sealing compound must be used t...

  • Page 4

    4 e2 e1 e4 e3 e5a e5 e6 e7.

  • Page 5

    5 installation f1 from the inside: fit the spigot through the fixing hole, with the connector socket cut out at the top. Ensure that the rubber seal is correctly located over the four lugs on the spigot. F2i window from outside: place the outdoor grille assembly with the louvres slanting downwards, ...

  • Page 6

    6 f3i/ ii f4a f4b f5 f9 f10 f6 f8 f7 for speed control refer to the relevant fitting and wiring instructions supplied with the wired/ wireless control..

  • Page 7

    7 (a) roof light all t-series roof models are designed to fit directly into horizontal and sloping glass including wired cast and sealed double glazing up to 32mm thick. For materials of greater thicknesses extended fixing rod sets are available, allowing the unit to be fixed through a spacing of up...

  • Page 8

    8 wiring the connector socket • ensure that the supply (voltage, frequency and phase) complies with the rating label. • this appliance must be earthed. F11remove the top cover from the connector socket by undoing the 2 retaining screws. F12 lift up lever and slide out top cover. F13loosen cable clam...

  • Page 9

    9 isolate from the power supply prior to any maintenance and cleaning user instructions • at intervals appropriate to the installation, inspect and clean the fan to ensure there is no build up of grease or dirt on the impeller or the motor. • the motor is fitted with sealed for life bearings and doe...

  • Page 10

    10 reassembly - allow the components to dry before reassembly g12 replace the outdoor grille with the louvres slanting downwards, and the vent-axia logo at the top of the grille. Tighten the retaining screw located at the bottom of the grille. G13 align the impeller with the locating pins on the mot...

  • Page 11

    11 g11 g12 g13 g17 g18 g19 g10 g14b g15 g16 g14a.

  • Page 12

    12 head office: fleming way, crawley, west sussex rh10 9yx tel: 01293 526062 fax: 01293 551188 internet site at: www.Vent-axia.Com vent-axia sales centres england & wales national call centre scotland newton road, crawley west sussex telephone: 0141 429 1166 rh10 9ja fax: 01293 565169 telephone: 012...