Vents VUE2 200 P User manual - page 6
www.ventilation-system.com
6
TECHNICAL DATA
The unit is designed for indoor application with the ambient temperature ranging from +1 °C up to +50 °C and relative humidity up to 80 %.
Hazardous parts access and water ingress protection rating:
• IP 44 for the unit motors;
• IP 22 for the assembled unit connected to the air ducts.
Designation of the unit series, main overall and connecting dimensions as well as the unit view and technical parameters of the unit
are shown in fi gure and table below.
The unit design is constantly being improved, so some models can slightly diff er from those ones described in this manual.
597
864
518
766
Ø12
Ø125
222
OVERALL DIMENSIONS OF THE UNIT, MM
UNIT TECHNICAL DATA
Ventilation mode (speed)
LOW (low)
MED (medium)
MAX (maximum)*
Unit supply voltage, 50 Hz [V]
1 ~ 230
Maximum fan power [W]
67
104
142
Fan current [A]
0,58
0,63
0,68
Maximum air capacity [m
3
/h]
80
143
220
R.p.m.
1120
1890
2910
Sound pressure level at 3 m distance [dB(A)]
20
28
36
Maximum transported air temperature [°C]
from -25 ° C to +40 ° C
Casing material
aluzinc
Insulation
foamed polypropylene, 10 mm
Filter: extract/intake
pocket G4
Connected air ducts diameter [mm]
ø 125
Heat recovery effi
ciency
up to 89 %
Heat exchanger type
cross fl ow, 2 items
* — maximum speed is activated by a signal from peripheral control elements: control panel, humidity sensor, thermostat, CO2 sensor etc.
MODIFICATIONS
Model
VUT 200 P
VUE2 200 P
VUTE2 200 P
Heat exchanger material
aluminum
polymerized cellulose
aluminium / polymerized cellulose