Verine Carmelo 1150 NHWV00RN NG Installation, User And Servicing Instructions - page 4
Page 4 of 14
Before fitting this appliance, ensure that the following components are enclosed
a)
Upper & Lower Firebox complete with burner and controls.
b)
Installation, Servicing & Users Instructions
c)
1 Packet of Burner fill granules
d)
Roll of sealing tape
e)
1 Handset Control unit, 1 Power Supply Unit.
f)
Flue Gather and fixings
g)
1 Pair Legs with adjustable feet.
h)
(Optional) - Coal, Pebble, Log, or Driftwood Pack as selected.
A
PPLIANCE DATA
NHWV00RN
NHWV00RP
GAS TYPE
NATURAL GAS
PROPANE
SUPPLY
PRESSURE
20mb
37mb
HEAT INPUT
14.3kW Gross
11.4kW Gross
INJECTOR SIZE
Ø 3.0mm
Ø 1.7mm
GAS CONNECTION
8 mm Compression
WEIGHT
45kg
G
ENERAL
I
NSTALLATION
R
EQUIREMENTS
Fitting the Appliance
1a
United Kingdom; The law demands that all gas appliances are installed by a
qualified installer in accordance with the current
GAS SAFETY (INSTALLATION
AND USE) REGULATIONS. The installation must comply with these installation
instructions and all relevant parts of Local and National Building Regulations or
Building Standards (Scotland) (Consolidation) Regulations and those relevant
recommendations of the following British Standards.
BS 5871: Parts 2 & 3, BS 8303, BS 5440: Parts 1 & 2, BS 1251, BS 6891
1b
Eire; This appliance should be installed in accordance with the rules in force. The
installation must be carried out by a Competent Person and installed in accordance
with the current edition of I.S.813 ‘Domestic Gas Installations’ and the current
Building Regulations.
2
This
appliance
can
be
fitted into fireplaces
FIGURE 1