WABCO smatrboard User Manual - page 14
Maintenance / Cleaning / Disposal
14
SmartBoard Display / Controller (EN)
6
Performing diagnostics
Abb. 9
Menu message
1
System providing the message
2
Affected component
3
Type of error (code)
The diagnostics are carried out using the
diagnostics interface of the trailer EBS E
or the ISO plug-in connection via CAN.
The SmartBoard device must be
connected to the trailer EBS for this and
the vehicle supplied with power by the
ABS socket.
The diagnostics enable the following
functions:
– Display of diagnostic messages
– SmartBoard parameter setting
– Update of the SmartBoard's internal
operating software
– Saving a start screen (splash image)
to the SmartBoard
To perform diagnostics, you require:
– a suitable diagnostic connection
– Hardware: PS / Laptop and
Diagnostic Interface Set
– Diagnostic software
Also follow the SmartBoard
device operating instructions for
reading the code messages.
The code messages are specific for the
installed system/components
(TEBS D / TEBS E / IVTM).
Read error type (code)
Read and evaluate the message in
accordance with the displayed error
type (Abb. 9/ 3).
SB - 004
1
2
3
Code
Meaning
00.
Value too high
01.
Value too low
02.
Data is irregular or incorrect
03.
Overvoltage / short circuit
to 24 V
04.
undervoltage / short circuit
to ground
05.
Supply-line interruption
06.
Power too high or power circuit
laid to ground
07.
Air gap too large
08.
Slip
09.
Signal failure
10.
Upward/downward jump
11/12
See error information
13.
Characteristic curve error
14.
Special errors / see error information
15.
See error information / residual pres-
sure