Wacker Neuson DPU 5045H Operator's Manual - page 18
T00467GB
16
MAINTENANCE
Maintenance schedule
Component
Maintenance work
Maintenance interval
External hardware
Check for tightness.
approx. 8 hours after
initial start-up
Drive engine
First oil change and filter.
25 hours after initial
Valve clearance
Cold engine: Check valve clearance, and adjust
start-up
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Air filter
Check dry type air filter - clean or replace filter
daily
cartridge if necessary (pay attention to the
maintenance indication).
Drive engine
Check oil level, if nec. top up oil.
Centre pole height
Regrease.
weekly
setting, transport
lock
V-belt
Check V-belt, if. nec. replace.
monthly
Protective frame,
Check attachment screws for tight fit.
central lifting point
Tow-bar head
Check oil level, top up if necessary.
Drive engine
Oil change, change oil filter.
every 250 h
Keep cooling fins free of dirt, clean dry.
Retighten all accessible screw connections.
Exciter
Oil change.
Battery
Check acid level, if nec. top up with distilled water.
Valve clearance
Cold engine: Check valve clearance, and adjust
if necessary.
Inlet valve 0,1 mm - outlet valve 0,2 mm.
Fuel filter
Change filter.
every 500 h