T00467GB
18
MAINTENANCE
Exciter
Oil
Check oil level:
1. Position vibration plate horizontally.
2. Open filler bore (30).
3. The oil level must reach the start of the thread of the filler bore (30).
4. If necessary, pour in Fuchs Titan Unic 10W40 MC through filler bore (30) (use funnel 0,75 l).
5. Close filler bore (30).
Changing the oil:
1. Open filler bore (30).
2. Tilt vibration plate and keep it tilted until the oil has run out.
3. Place vibration plate in horizontal position.
4. Pour in 0,75 l Fuchs Titan Unic 10W40 MC through the filler bore (30).
5. Close filler bore (30).
☛
ATTENTION! Do not pour in too much oil!
Exciter V-belt
It is not necessary to retighten the V-belt owing to the use of
the automatic centrifugal clutch.
Should the V-belt width fall below 15,5 mm the V-belt must be
replaced.
Changing the exciter V-belt:
1. Remove belt guard (31).
2. Undo screw (32).
3. Remove button (33), belleville spring (34), seal (35) and front
segment of the V-belt pulley (10).
4. Change exciter V-belt (12).
5. Assemble the components in reverse order; make sure that the
coloured marking on the pin (36) coincides with the marking on
the V-belt pulley (10)
☛
ATTENTION! Do not oil or grease clutch components (will