Wacker Neuson GV 7000A Operator's Manual - Operation
Operation
GV 7000A / 7003A
3
0
wc_tx001624gb.fm
4.9
Before Starting
4.9.1
Read and understand safety and operating instructions at beginning of
this manual.
4.9.2
Read and understand the meanings of all warning and operating
labels.
4.9.3
Check:
•
oil level in engine.
•
fuel level.
•
condition of air cleaner.
•
tightness of external fasteners.
•
condition of fuel lines.
4.10 Starting
See Graphic: wc_gr001299
4.10.1 Disconnect all loads from the generator and place main circuit breaker
in open position (e2) (GV 5003A, GV 7003A).
4.10.2
Open fuel valve
(a).
Note: If engine is cold, move choke (b) to closed position—pull out.. If
engine is hot, set choke to open position—push in.
4.10.3
Turn engine switch to "ON"
(c1)
and pull starter rope
(d).
Note: If the oil level in the engine is low, the engine will not start. If this
happens, check oil level and add oil as needed.
4.10.4
Open choke as engine warms
(b).
4.10.5
Place main circuit breaker in closed position
(e1) (GV 5003A, GV
7003A). Allow the engine to warm up for a few minutes before
attaching loads.
DANGER
f
Carbon monoxide. Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide (CO). This is a poison you cannot
see or smell. If you can smell the generator exhaust, you are breathing CO. But
even if you cannot smell the exhaust, you could be breathing CO.