Wacker Neuson GV 7000A Operator's Manual - page 39
of
44
7 Technical data
100_0402_td_0004.fm
39
7
Technical data
7.1
GV 7000
Designation
Unit
GV 7000A
GV 7000A
Item no.
0009348
0009353
Maximum Output (LTP)
kVA
7,2
Continuous Output (COP)
kVA
6,0
Net installed power
kW
5,47
Type
Single voltage, single phase Brushless, capacitor regulator
system
AC Voltages Available
V
230
Phase
~
1
Frequency
Hz
50
Power Factor
cos
0,9
AC receptacles
230V 16A 1~ CEE7/4,
230V 32A 1~ CEE
230V 16A 1~ CEE7/5,
230V 32A 1~ CEE
AC receptacles
qty
2
Main Circuit Breaker
A
25
Length
mm (in)
729 (28.7)
Width
mm (in)
500 (19.7)
Height
mm (in)
536 (21.1)
Weight
kg (lb)
76,0 (167.6)
Sound pressure level L
pA
* dB(A)
77,0
Standard
DIN EN ISO 11201
Sound power level L
WA
measured
guaranteed
dB(A)
97,0
97,0
Standard
2000/14/EC
* Measured in 4 m away.