Waeco PerfectPower PP1002 Installation And Operating Manual - page 17
EN
Fastening and connecting the inverter
PerfectPower
36
Sample circuit diagram legend:
➤ Install a residual current circuit breaker in the socket distribution circuit.
Setting grounding bridge (fig. 4, page 4)
e
Warning – Danger of electrocution!
The grounding bridge may only be connected by a trained
professional who is familiar with the relevant VDE (German
Engineering Society) regulations.
I
Note
The grounding bridge plug is always plugged into socket “FG”
(insulated AC current) when delivered.
➤ Unscrew the top four fastening screws (2) on the front of the device with
a hex key.
➤ Take off the cover (1).
e
Caution
The grounding bridge is changed with sockets “FG” and “N + FG”.
Do not alter the other sockets, otherwise the device may be
damaged.
➤ Remove the plug (3) from socket “FG” (4).
➤ Insert the plug (3) into socket “N + FG” (5).
➤ Replace the device cover (1) and fix using the screws (2).
No. in fig. 6,
page 5
Explanation
1
230 V
AC
power source
2
Additional devices, e.g. battery charger, refrigerator
3
DC power source (battery)
4
Inverter
5
Grounding bridge set
(At delivery: not set, shown by dotted line)
6
Circuit breaker (residual current circuit breaker)
7
Socket distribution circuit for consumers
_PP1000_PP2000.book Seite 36 Freitag, 18. November 2011 2:53 14