WAGNER AG-14 Owner's Manual - Introduction
12 AG-14
GB
Introduction
This airless spray gun is to be used for the
high pressure atomization of liquid coating
materials.
UsingtheGunTriggerLock
Always engage the gun’s trigger lock when the
gun is not in use.
1. To lock the trigger, rotate the trigger lock
backward until it stops.
2. To unlock the trigger, rotate the trigger
lock forward until it is vertical.
1
2
Gun locked
(gun will not
spray)
Gun unlocked
(gun will
spray)
Setup
Neverattempttoassemble,
change,orcleanthegun,tip,or
tipguardwithoutfirstrelieving
pressurefromthespraysystem.
Followthe“PressureRelief
Procedure”inthesprayer’s
Owner’sManual.
Alwaysuseatipsafetyguard
foraddedprotectionagainst
injection.Bewarethattheguard
alonewillnotpreventinjection.
Nevercutofftipguard!Always
engageguntriggerlockwhenthe
gunisnotinuse.Beforeservicing
equipment,consultOwner’s
Manualsandfollowallwarnings.
1. Set up the sprayer. Refer to the
instructions in the sprayer’s Owner’s
Manual.
2. Attach a grounded, airless spray hose to
the material inlet on the gun. Using two
wrenches (one on the gun and one on
the hose), tighten securely.
3. With the tip and tip guard off the gun,
start the sprayer. Flush and prepare the
spray system according to the sprayer’s
Owner’s Manual. Inspect the spray
system to make sure that all fittings are
secure and that there are no leaks.
4. Perform the “Pressure Relief Procedure”
described in the sprayer’s Owner’s
Manual.
5. Using a pen or similar object, insert the
tip seal (3) and seal (4) into the back
of the tip guard (2). Press in for final
adjustment.
6. Insert the tip (1) into the slot on the tip
guard.
1
2
3
4
7. Thread the tip guard onto the gun.
Position the tip guard in the desired
spraying position, then tighten securely.
i
Thearrowonthetiphandle
shouldbepointingintheforward
directionforspraying.
Operation
1. Make sure the arrow on the tip handle
is pointing in the forward direction for
spraying.
2. Start the sprayer. Refer to the instructions
in the sprayer’s Owner’s Manual.
3. Adjust the fluid pressure on the sprayer
until the spray is completely atomized.
Always spray at the lowest pressure
necessary to get the desired results.
i
Thespraytipdeterminesthesize
ofspraypatternandcoverage.
Whenmorecoverageisneeded,
usealargertipinsteadof
increasingfluidpressure.
4. To clear a clogged tip:
a. Rotate the tip 180º so that the arrow on
the tip handle is pointing opposite the
spray direction.
b. Trigger the gun once so that the
pressure can blow the clog out.
Attention
Neverpullthetriggermorethan
onceattimewiththetipinthe
reverseposition.
c. Continue this procedure until the tip is
clear of the clog.