WAGNER Control Stainer 150 Owner's Manual - Cleanup
10
en
cleanUP
1
2
3
(a)
4
(b)
(c)
5
Groove
Tab
Notch
cleanUP notes
i
When cleaning, use the appropriate cleaning
solution (warm, soapy water for water-based
coatings, and mineral spirits for oil-based
coatings.
Special cleanup instructions for use with
flammable solvents (must have a flashpoint
above 100ºF (38ºC):
•
Always flush spray gun outside.
•
Area must be free of flammable vapors.
•
Cleaning area must be well-ventilated.
•
Do not submerge turbine!
i
For basic quick-cleaning between color
changes, fill the material container with
cleaning solution and spray the cleaning
solution through the gun and into a waste
container.
1.
Turn turbine OFF.
Remove the container and empty any remaining material.
Thoroughly rinse the material container with warm, soapy
water (or mineral spirits for oil-based materials).
2.
Disassemble the spray gun and clean all parts with warm
soapy water (or mineral spirits for oil-based materials).
3.
Clean the air vent (a) on the suction tube with a soft
bristled cleaning brush.
4.
Separate the turbine from the nozzle. Clean the rear of
the nozzle (b) with the appropriate cleaning solution. Use
a thin layer of petroleum jelly to lubricate the O-ring (c).
5.
Reassemble the spray gun.
i
When replacing the nozzle seal, make sure
the groove in the seal is facing outward.
Make sure the tab in the spray gun head is
aligned with one of the notches in the nozzle.
i
For a video showing cleanup of the Control Stainer150, visit:
www.wagnerspraytech.com/controlstainer150