Wahlberg 241 User Manual - page 15
15
805.241.011
Date: March 22
rd
, 2017
MODE 2 - Positioning with MANUAL reset
The winch is manually reset on the DMX channels 6 or 7. The top-position is, because of this,
also set manually, which makes it possible to decide the position of the top-position.
We suggest anyway that it is set near by the motor-house. When the winch has been reset, it is
possible to use it in positioning mode.
MODE 3 – No function assigned
The winch stops
MODE 4 – No function assigned
The winch stops
MODE 5 – No function assigned
The winch stops
MODE 6 – No function assigned
The winch stops
Warning! MODE 7 and MODE 8 is only for service and tests!
Warning! Before running the winch in MODE 7 or MODE 8, ensure that the area beneath the
winch is cleared so no people can be harmed.
MODE 7 – Manual run up (no DMX needed)
The winch runs up with the speed set on the DMX-selectors. This function can be used as a test-
function or in association with on- and off-applying of wire.
E.g. Set the winch to MODE 7 and the DMX address to 100, for a slow movement, or set the
DMX address to 500 for fast movement.
MODE 8 – Manual run up (no DMX needed)
The winch runs down with the speed set on the DMX-selectors. This function can be used as a
test-function or in association with on- and off-applying of wire.
E.g. Set the winch to MODE 8 and the DMX address to 100, for a slow movement, or set the
DMX address to 500 for fast movement.
Table 2 - Overview of MODE functions
MODE
Function
Note
0
Neutral function – motor stops
1
Positioning with auto TOP reset
2
Positioning with manual TOP reset
3,4,5,6
Stops the motor unless specified otherwise
7
Manual run up (no DMX needed)
Warning! Only for service and tests!
8
Manual run down (no DMX needed)
Warning! Only for service and tests!
9
Used for re-calibrating overload see page 18