Waldorf RN8910GC Installation And Operation Manual - page 14
12
Operation
Oven ‘Shut-Down’
1.
To ‘Shut Down’ oven, turn oven thermostat to ‘0’ position, oven main burners will go out.
2.
Turn gas control valve to 'OFF' position and this will extinguish pilot burner. (To relight pilot burner,
refer to ‘Oven Pilot Ignition’ above).
3.
Turn ‘OFF’ electrical power at mains supply, (green) power indicator light will extinguish.
NOTE: If main burner has recently been turned 'OFF' and you want to re-light oven, the interlock
will not allow the gas valve to be turned to main burner position until the interlock has reset
(Approximately 1 minute). DO NOT FORCE GAS VALVE TO MAIN BURNER POSITION
UNTIL INTERLOCK HAS RESET, as this will damage gas control valve.
IMPORTANT:
Should any abnormal operation like;
- ignition problems,
- abnormal burner flame,
- burner control problems,
- partial or full loss of burner flame in normal operation, be noticed, appliance requires
IMMEDIATE service by a qualified service person and should not be used until such service
is carried out.