Waldorf RN8910GC Installation And Operation Manual - page 6
4
Specifications
Gas Supply Requirements
- Australia / New Zealand Only:
- UK Only:
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
2.
(
*
) Measure burner operating pressure at manifold test point with two burners operating at full
setting. Operating pressure is ex-factory set, through appliance regulator and is not to be
adjusted, apart from when carrying out gas conversion, if required. (Refer to ‘Gas Conversion’
section for details).
Gas Connection
Gas supply connection point is located at rear of appliance, approximately 130mm from right hand
side, 30mm from rear and 655mm from floor and is reached from beneath appliance. (Refer to
‘Dimensions’ section).
Connection is ¾" BSP male thread.
Electrical Supply Requirements
230-240 V a.c, 50 Hz, 1.6A, 1P+N+E.
0.4kW.
Oven Fan Motor - 100W.
Natural Gas (G20)
Propane (G31)
Open Burner
(each)
Oven
Open Burner
(each)
Oven
Heat Input (nett)
Nominal
6.5 kW
7.8 kW
6.5 kW
7.8 kW
Reduced
1.75 kW
---
1.75 kW
---
Gas Rate (nett)
Nominal
0.69 m
3
/hr
0.83 m
3
/hr
0.51 kg/hr
0.61 kg/hr
Reduced
0.19 m
3
/hr
---
0.14 kg/hr
---
Supply Pressure
20 mbar
37 mbar
Operating Pressure
9.5 mbar (*)
26 mbar (*)
Gas Connection
3
/
4
” B.S.P. Male
Natural Gas
LP Gas (Propane)
Input Rate (N.H.G.C.)
- each Open Burner
28 MJ/hr
(26,540 Btu/hr)
28 MJ/hr
(26,540 Btu/hr)
- Oven
30 MJ/hr
(28,434 Btu/hr)
30 MJ/hr
(28,434 Btu/hr)
Supply Pressure
1.13 - 3.40 kPa
(4.5” - 13.5” w.c.)
2.75 - 4.50 kPa
(11” - 18.0” w.c.)
Operating Pressure
0.95 kPa (*)
(3.7” w.c.)
2.6 kPa (*)
(10.0” w.c.)
Gas Connection
3
/
4
” B.S.P. Male