Waldorf RN8910GC Installation And Operation Manual - page 23
21
Gas Conversion and Specifications
Gas Specifications
- Australia / New Zealand Only
- UK Only
Appliance Classification
Category:
II
2H3P.
Flue Type:
A
2.
*
Measure burner operating pressure at manifold test point with burner operating at full setting.
Operating pressure is ex-factory set, through appliance regulator and is not to be adjusted,
apart from when converting between gases, if required. (Refer to ‘Gas Conversion’ section for
details).
Natural Gas
LP Gas (Propane)
Open Burner
Main Burner Injectors
Ø 2.45mm
Ø 1.50mm
Pilot Burner ('PF' Option Only)
0.30
0.20
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
1.13 - 3.40 kPa
2.75 - 4.50 kPa
Operating Pressure
0.95 kPa (*)
2.6 kPa (*)
Gas Regulator Cap Screw
Natural Gas
(G20)
Propane
(G31)
Open Burner
Main Burner Injectors
Ø 2.30mm
Ø 1.40mm
Pilot Burner ('PF' Models Only)
0.30
0.20
Oven
Main Burner
Ø 2.60mm
Ø 1.60mm
Pilot Burner
0.35
0.23
Burner Aeration Setting
Fully Open
Fully Open
Supply Pressure
20 mbar
37 mbar
Operating Pressure
9.5 mbar
26 mbar
Gas Regulator Cap Screw