Wallace International Kinetic DC 10FW Installation And Maintenance Manual - page 25
Installing the Drive on Gate Post
1-6
Rev:
A
Programming the Initial Setup Menu:
Several sequential displays present information which must be configured before Kinetic operator will
function. Once the configuration is complete, the information is retained even when a power loss occurs.
Table 1-1. Menu Mode Navigational Buttons
To Edit the Menu
To navigate through
the SELECTIONS
To choose what is
on the display
To navigate
between menus
Press SELECT
Two top characters blink.
Press NEXT.
Continue pressing NEXT
to view all selections.
Press SELECT.
Blinking characters become
static.
Press NEXT or PREV.
Advance – Press NEXT
Previous – Press PREV.
Note
: Programming the Setup Menu is usually a one-time occurrence unless factory defaults are reinstated
through the Installer Menu. The RESET and MENU buttons do not function during the initial
configuration of the Setup Menu.
Figure 1-11
SELECTIONS
0
- No Usage Class set.
1
- Single family residential up to four units.
2
- Multi-family, hotel etc.
3
- Industrial use, not for general public
4
- Guarded and monitored facility, not for general public
SELECTIONS
0
- No handing set. Gate will not move until handing is set.
Looking at gate from secure side:
L
- If the gate slides open to the left.
R
- If the gate slides open to the right.
SELECTIONS
0
- Gate weight not set.
Kinetic DC 15W
1
- Gate weight 0 to 400lbs (0 to 181kg)
2
- Gate weight 401 to 800lbs (181 to 363kg)
3
- Gate weight 801 to 1100lbs (363 to 499kg)
4
- Gate weight 1101 to 1500lbs (499 to 680kg)
Kinetic DC 10FW
1
- Gate weight 0 to 250lbs (0 to 114kg)
2
- Gate weight 251 to 500lbs (114 to 227kg)
3
- Gate weight 501 to 750lbs (227 to 340kg)
4
- Gate weight 751 to 1000lbs (340 to 454kg)