WANDERS KANDA User Manual And Installation Manual - Installation Instructions
22
Installation instructions
General instructions
Your gas hearth must only be installed by a certified
JOTUBMMFS BOE POMZ JO DPNCJOBUJPO XJUI UIF8"/%&34
concentric pipe system. Only then will the hearth be
approved according to the European CE standards for
gas appliances. We will not give any guarantees if the
gas hearth is fitted and/or installed in an incomplete or
improper manner. The pipe system consists of an inner
pipe with a diameter of 100 millimetres and an outer
pipe with a diameter of 150 millimetres.
The appliance may only be installed and fitted by a cer-
tified installer in accordance with current universal gas
piping regulations and according to the installation in-
structions mentioned below. Furthermore, the national
and local rules and regulations on placing and using
closed gas appliances shall be applicable. Only certi-
fied installers are authorized to change the preset values
(in line with the regulations) or make any other adjust-
ments.
Before installing the appliance, the installer must check
whether the information on the type tag of the fireplace
corresponds with the gas type and gas pressure to which
the appliance is connected. If it does not match, it is not
allowed to connect the gas unit.
Placing
The gas hearth must not be built into the wall. The dis-
tance from the hearth to the rear wall must be at least 10
DN5IFHBTIFBSUINVTUCFQMBDFEPOBnPPSUIBUJTTPMJE
enough to hold it.
The gas hearth can be placed in a crack-free and/or me-
chanically ventilated home without difficulty. There is
no need for extra ventilation for combustion, or for a
smoke and fire vent. Waste gases are discharged by nat-
ural draught via the inner pipe into the open. The oxygen
needed for burning the fire is supplied from the space
between the pipes. This is the reason that no insulation
must be placed between the inner and the outer pipe.
Insulation
%VFUPUIFIJHIUFNQFSBUVSFTPGUIFFYUFSJPSXBMMT VQUP
approximately 150 °C or 300 °F) it is prohibited to have
any combustible materials close to the channel system.
The entire concentric pipe system should be encased
(heat resistant) from the place where it is out of sight up
to the outlet in the exterior wall. Ventilate the encased
DPODFOUSJDQJQFTZTUFNCZQMBDJOHBHSJEOFBSUIFnPPS
BOEUIFDFJMJOHPOFWFSZnPPS6TFVOJWFSTBMXBMMDMJQT
with a diameter of 150 mm for anchoring the concentric
pipe system.
If an existing chimney is used, first make sure whether
the chimney is sufficiently insulated and with sufficient
diameter to accommodated the concentric pipe system.
If the chimney was previously used as a wood-burning or
coal-fired stove, the chimney must first be professionally
DMFBOFE:PV NVTU VTF TQFDJBM 8"/%&34 DPOOFDUJOH
sets for connecting a gas hearth to an existing chimney.
Gas connection
t 5IFIFBSUIJTTVQQMJFEXJUIBTFSWJDFQBOFMBTTUBOE
-
ard accessory.
t 1MBDFUIFTFSWJDFQBOFMPOUIFSJHIUPSPOUIFMFGUTJEF
of the stove.
t 6TF B GFFE QJQF XJUI BO BQQSPWFE (w TUPQ DPDL
with coupling.
t 5IF DPOOFDUJPO PG UIF BQQMJBODF JT MPDBUFE JO UIF
TFSWJDFnBQ
t %FBFSBUFUIFTVQQMZQJQFCFGPSFmUUJOHBOEGBTUFOJOH
the appliance.
t "WPJEUFOTJPOPOUIFDPOUSPMDPDLBOEUIFEVDUTUFO
-
sion increases the chance of gas leakage.
General
instructions
22
Placing of the concentric channel system
23
Placing possibilities of the pipe system
23
Opening the door
26
Placing the log set
26
Mounting the collar shaft
26