  • Page 1

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 1 debonaire duplo 1200-1600-2000-2400-2800 custom fire duplo — gas burner installation instructions flue ...

  • Page 2

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 2 points to consider prior to installation installation order of operations prior to construction and ins...

  • Page 3

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 3 custom gas firebox dimensions minimum flue height flue height 3600 measured from top of adaptor 3600 he...

  • Page 4

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 4 minimum alcove clearances frameout detail description 1200 1600 2000 2400 2800 overall timber width i 1...

  • Page 5

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 5 venting the burner cavity only - general important note the burner and the burner base are to be vented...

  • Page 6

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 6 firebox installation this is a general installation guide only – contact a “nzhha installer” or gas fit...

  • Page 7

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 7 plan front elevation & cross section firebox is to be bolted to supporting framing or block work vent &...

  • Page 8

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 8 flue details dimensions double flue system minimum flue height flue height 3600 measured from top of ad...

  • Page 9

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 9 flue penetration vented through alcove (single lined flue system) test report number date of report 04/...

  • Page 10

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 10 chimney chase flashing details setting add gas cowl height “chimney chase flashing” and “air ventilati...

  • Page 11: 3D View

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 11 flue height minimum details frame out and trim out details for chimney chase option x – singled lined ...

  • Page 12

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 12 combustable mantel clearances note: for combustable floors minimum floor pro- tector of 300mm (a) must...

  • Page 13: Data Plate

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 13 general notes warnings: warning; any modification of the appliance that has not been approved in writi...

  • Page 14

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 14 debonair series of decretive flame effect fires flued gas appliances all gas fires requir ing war ming...

  • Page 15

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 15 vermiculite (course) (to be set by gasfitter) coals and logs (to be set by gasfitter) gloves should be...

  • Page 16

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 16 view of general components the main isolating switch push switch to on and set to high / low as needed...

  • Page 17

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 17 once the unit is installed: (to be tested by the electrician and the gas fitter for correct operation)...

  • Page 18

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 18 open windows and doors do not light any gas appliance do not use any electrical appliance or switches ...

  • Page 19

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 19 fault finding 1: pulse switch depressed and no spark at the electrode: check earth wire connected main...

  • Page 20: Warranty

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 20 warmington industries recommend annual servicing of your gas appliances by an approved warmington deal...

  • Page 21

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 21 main & hi / low switch connection ht leads white lead – spark red lead - rectifier gas burner and elec...

  • Page 22

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 22 procedure for the test and comissioning of your decorative fire. Ensure gas supply and the power suppl...

  • Page 23

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 23 diagram b ( showing control valve with test points and adjusting screw ). After checking the pressure,...

  • Page 24

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 24 installing burner & control box location step 1. Step 2. Step 3. Step 4. Step 5. Place control box sup...

  • Page 25

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 25 gas starter schematic diagram.

  • Page 26

    12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 26 general notes notes: these installation and operating instructions should be kept in a safe place. Sho...