Once the unit is installed: (to be tested by the electrician and the gas fitter for correct operation)
Ensure that all gas connections are leak free.
Ensure all components and electrical connections are completed and firmly secured.
Ensure the unit is free of obstruction and any flammable material.
Switch on main power switch (supplied by electrician).
Depress the pulse switch (supplied by electrician).
The high frequency spark electrode will operate. At the same time the gas solenoid valve will open allowing the
gas to flow to the burner. If the unit does not light it will automatically shut down.(On flame failure)
The Main power switch should be switched off when burner is not being used to ensure that there is no accidental
operation of the unit.
TESTING BURNER
POINTS OF SAFTEY—To the Customer /Home-Owner
Your Warmington Gas Decorative Fire operates on the principle of dual radiant and convected heat. Therefore it is important to
observe the following precautions associated with any heating appliance or open fire.
Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build-up of hazardous gases
within the room.
The fire is not intended for the drying of clothing, bedding etc.
Avoid installing this appliance in high traffic areas, strong draughts or near drapes or furniture.
Avoid using aerosols when the appliance is operating.
Avoid anyone leaning against or lying directly in front of the fire while operating.
Do not place anything objects into or against the gas fire at any stage.
The fire may release a small amount of smoke on its first start up which may take 1 or 2 hours to dissipate . This is part of
the curing process so ensure there is adequate ventilation within the room.
Always use a registered Gas Fitter or Electrician for installing and maintenance work
Always use certified gas cylinders that have been tested and are safe to use.
Never modify your gas appliance or its settings from those specified by the manufacturer.
APPLIANCE SAFETY Any gas fir e appliance shall comply with the safety r equir ements of the cur r ent standar ds listed
under “Related documents” in this specification.
ELECTRONIC CONTROL SYSTEMS Any gas fir e appliance fitted with manual or pr ogr ammable electr onic contr ol
systems shall be tested and/or approved by a recognised person or authority.