12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 1 debonaire duplo 1200-1600-2000-2400-2800 custom fire duplo — gas burner installation instructions flue ...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 2 points to consider prior to installation installation order of operations prior to construction and ins...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 3 custom gas firebox dimensions minimum flue height flue height 3600 measured from top of adaptor 3600 he...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 4 minimum alcove clearances frameout detail description 1200 1600 2000 2400 2800 overall timber width i 1...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 5 venting the burner cavity only - general important note the burner and the burner base are to be vented...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 6 firebox installation this is a general installation guide only – contact a “nzhha installer” or gas fit...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 7 plan front elevation & cross section firebox is to be bolted to supporting framing or block work vent &...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 8 flue details dimensions double flue system minimum flue height flue height 3600 measured from top of ad...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 9 flue penetration vented through alcove (single lined flue system) test report number date of report 04/...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 10 chimney chase flashing details setting add gas cowl height “chimney chase flashing” and “air ventilati...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 11 flue height minimum details frame out and trim out details for chimney chase option x – singled lined ...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 12 combustable mantel clearances note: for combustable floors minimum floor pro- tector of 300mm (a) must...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 13 general notes warnings: warning; any modification of the appliance that has not been approved in writi...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 14 debonair series of decretive flame effect fires flued gas appliances all gas fires requir ing war ming...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 15 vermiculite (course) (to be set by gasfitter) coals and logs (to be set by gasfitter) gloves should be...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 16 view of general components the main isolating switch push switch to on and set to high / low as needed...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 17 once the unit is installed: (to be tested by the electrician and the gas fitter for correct operation)...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 18 open windows and doors do not light any gas appliance do not use any electrical appliance or switches ...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 19 fault finding 1: pulse switch depressed and no spark at the electrode: check earth wire connected main...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 20 warmington industries recommend annual servicing of your gas appliances by an approved warmington deal...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 21 main & hi / low switch connection ht leads white lead – spark red lead - rectifier gas burner and elec...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 22 procedure for the test and comissioning of your decorative fire. Ensure gas supply and the power suppl...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 23 diagram b ( showing control valve with test points and adjusting screw ). After checking the pressure,...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 24 installing burner & control box location step 1. Step 2. Step 3. Step 4. Step 5. Place control box sup...
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 25 gas starter schematic diagram.
12 september 2016 due to continued product improvement, warmington ind ltd reserves the right to change product specifications without prior notification. All dimension are in mm………….Copyright © 26 general notes notes: these installation and operating instructions should be kept in a safe place. Sho...