Warmington Traditional Fire - Gas 1000 Installation Instructions Manual - page 9
23 November 2016
Due to continued product improvement, Warmington Ind LTD reserves the right to change product specifications without prior notification.
All Dimension are in mm………….Copyright ©
9
FLUE DETAILS DIMENSIONS
Minimum Flue Height
Flue height
3600
Measured from top of adaptor
B + 3600
FLUE SYSTEM INSTALLATION GUIDE
This is a general installation guide only – Contact a “NZHHA Installer” or Gas Fitter for
Installation Advice.
1. Install the first length of flue pipe with the crimped end down, inside the Adaptor collar, ensure that the flue
pipe is sealed into the collar with exhaust sealant. Rivet the flue in 3 places around the Adaptor collar. Place a
bottom spacer around the flue pipe approximately 150mm above the adaptor collar. Secure in position by
tightening the screw and nut.
2. Install the second length of flue pipe with the crimped end down and fit by riveting in at least 3 places around
the flue pipe joint. Ensure that the flue is sealed into position with sealant.
3. Install the first section of flue pipe liner with the Crimped end up, over the flue pipe and over the spacer that is
fixed to the flue pipe. This spacer will keep the liner concentric about the flue pipe.
4. Position flue spacer at the flue pipe joint for every length of “Flue pipe” and “Liner”.
Repeat the Steps from 1 – 4 to the installed required height of the flue system. The flue system is to comply
with the current standards.
IF FLASHING CONE NEEDED:
1.
NOTE: The last length of flue pipe needs to extend past the liner so that when the ‘top spider’ and
the ‘flashing cone’ are fitted, that the ‘flashing cone’ and the ‘flue pipe’ are flush, or that the ‘flue pipe’ is
5mm lower that the ‘flashing cone’.
2.
Fit the ‘Top Spider’ into position, ensure that the legs of the spider are fitted inside the liner and that the
spider is positioned hard down onto the liner and tighten with the screw and nut.
3.
Place the ‘flashing cone’ over the ‘flue pipe’ and press hard down onto the ‘Top Spider’. (Note that the
‘flue pipe’ and the ‘flashing cone’ are either flush or the ‘flue pipe’ is 5mm lower than the ‘flashing cone’).
Ensure that the ‘flashing cone’ is clear for the venting from the ‘Liner’ and the ‘flue pipe’.
4.
Fit the ‘cowl’ to the top of the flue pipe. The ‘cowl’, ‘flashing cone’, and the ‘flue pipe’ can be secured to
each other with the uses of a stainless steel self tapping screw. This will allow the ‘cowl’ to be removed for
cleaning.
5.
Flue system may require bird proofing due to the installation and locations, discuss this with your installer
for the best advice.
6.
If the Flue system is installed into a ‘chimney chase’, allow for air vent as close to the top of the chase as
practical, or allow venting through the ‘chimney chase flashing’. A ‘venting flashing cone’ and a 25mm gap
around the liner with a ‘venting flashing cone-spider’ can be used.
a “the flue pipe shall extend not less than 4.6m above the top of the floor protector.”
b “ the minimum height of the flue system within 3 m distance from the highest point of the roof shall be 600mm
above that point.”
c “the minimum height of the flue system further than 3 m from the highest point of the roof shall be 1000mm
above the roof penetration.”
d “no part of any building lies in or above a circular area described by a horizontal radius of 3 m about the flue
system exit.”
Flue details
No:
TF 1500
TF 1200
TF 1000
Cowl
1
400
350
300
Top Spider
1
400
350
300
Cone
1
400
350
300
Flue Diameter
3
400
350
300
Liner Diameter
3
450
400
350
Spacer
3
300/350
350/400
400/450
NOTE:
Ensure that a standard tested Warmington Flue System is used on Warmington Fires.