Water Control Brassmaster Installation & Operation Manual - page 6
Maintenance / Warranty Information
All BrassMaster and BrassMaster Plus wa-
ter softeners feature the Assured Perfor-
mance Modular (APM) design. If you expe-
rience a failure of any valve component, the
brass module can be easily removed and
replaced with a factory remanufactured re-
placement module.
To remove module, index the bypass valve
to its “Bypass” position. Follow steps in
“Placing unit into service” to step valve
through all 4 cycles, but do not open bypass
valve. When this procedure is performed
with the bypass closed, it will relieve any
water pressure on the unit.
Remove the stainless-steel retainer pins at
the base of the module, loosen the clips at
the bypass valve, and disconnect the drain
line and brine line. The module will now
completely separate from the tank.
Please contact your dealer or Water Control
Corporation for module support.
Nearly all serviceable
parts lie within the
removable/
replaceable APM
module. This
eliminates costly
and me consuming
field repairs.
Forfactorymodulesupportcontact:
WaterControlCorporation
7150143
rd
AveNW●Ramsey,MN55303
Phone:1‐866‐405‐1268●Fax:763‐427‐5665