PROBLEM
CAUSE
CORRECTION
6. Iron in
conditioned
water
A. fouled mineral bed
A. check backwash, brine draw and
brine tank fill — increase frequency
of regeneration
7. Excessive
water in
brine tank
A. plugged drain line flow control
A. clean flow control
B. brine valve failure
B. replace brine valve
C. improper programming
C. check program — reset
D. faulty air check or safety float
D. replace complete safety float
assembly
8. Salty water in
service lines
A. plugged drain line flow control
A. clean flow control
B. plugged injector system
B. clean injector and screen
C. timer not cycling
C. replace timer
D. foreign material in brine valve
D. replace brine valve seat and
clean valve
E. foreign material in brine line
flow control
E. clean brine line flow control
F. low water pressure
F. raise water pressure
9. Softener fails
to draw brine
—
Yellow Light
Indication
A. drain line flow control is plugged
A. clean drain line flow control
B. injector is plugged
B. clean injector and port behind
injector
C. injector screen plugged
C. clean screen
D. line pressure is too low
D. increase line pressure to 25 psi
E. internal control leak
E. change seals, spacers and piston
assembly
F. improper programming
F. check programming — reset
G. probes scaled in chlorine generator
G. clean or replace chlorine generator
H. drawing air during regeneration
H. check brine line connections
I. electrical malfunction
I. replace board or wire harness
10. Control
cycles
continuously
A. broken or shorted micro-switch
A. determine if switch or timer is
faulty and replace
B. faulty cam operation
B. replace or reinstall cam
11. Drain flows
continuously
A. valve not programming correctly
A. check time program and
positioning of control
B. foreign material in control head
B. remove power head assembly
and inspect bore, remove foreign
material and check control in
various regeneration positions
C. internal control leak
C. replace seals and piston assembly
D. drive motor jammed in
regeneration
D. replace seals and piston, drive
motor, check for broken gears