Waterco 20 SC Owner's Manual - page 4
I pg 05
Waterco Hydrochlor®
INSTALLATION
These guidelines should be followed to install the Hydrochlor®:
a. Ensure that the chlorinator cell is the last piece of
equipment installed on the filtration system – this
is so the chlorine produced will not damage other
equipments such as heaters.
b. The cell may be installed above or below water
level. If it is below water level, please ensure that
an isolation valve is installed so the unit can be
serviced without losing water from the pool.
c. The cell may be mounted on different angles so
long as a gas trap is provided.
GAS TRAP: The cell must be positioned in such a
way as to provide a gas trap. The bottom of the
cell must be above the top surface of the pipe
from the previous piece of equipment, as per the
below diagram.
Installing the Power Pack
$IPPTFBMPDBUJPOGPSUIF)ZESPDIMPS¡1PXFS1BDLDMPTFFOPVHIUPUIF$FMM)PVTJOHBOEàMUSBUJPO
QVNQTPUIBUCPUINBZCFDPOOFDUFEEJTDPOOFDUFEFBTJMZ5IF)ZESPDIMPS¡1PXFS1BDLTIPVME
not be mounted in areas where chemicals are stored (e.g. acid and chlorine). Also ensure that the
Hydrochlor® Power Pack can be connected to the mains power outlet of the pool area.
Note that this outlet must meet the current applicable local standards at the time of installation.
5IF16.1TPDLFUPVUMFUJOUIFCBTFPGUIF)ZESPDIMPS¡T1PXFS1BDLJTEFEJDBUFEUPUIFàMUSBUJPO
pump only. Do not use a double adaptor to connect another pump as this will overload the system
and void warranty.
Installing/Connecting the Hydrochlor® Self Cleaning Cell
5IF$FMM)PVTJOHBTTFNCMZTIPVMECFQMVNCFEJOUPUIFQPPMSFUVSOMJOFBGUFSBMMPUIFSBDDFTTPSJFT
BOEQSJPSUPBOZIFBUJOHUBLFPGGT/PUFBOZXBUFSáPXEJSFDUJPOPOUIF$FMM)PVTJOH5IF$FMMXJMM
need to be removed from the Housing periodically for cleaning – do not place it where its removal
DBOCFEJGàDVMUPCTUSVDUFE
The Cell Cable is connected to the Cell Connector under the Hydrochlor® Power Pack cover.
Ensure that the 3 connections (2 for Cell Power and 1 for Gas Sensing) are
not loose. A loose connection is likely to cause arcing which may damage
the entire system.
NOTE:
Connect all plumbing to the Hydrochlor taking care
that all joints are
glued or tightened
securely to prevent leaking.
Allow 24 hours for glue (solvent) to set before starting the Hydrochlor.
EZY TIMER SETTING
Setting a New Time
I. Press
HOME
key to ensure current time is displayed.
II. Press
HOURS
key, to change hours.
III. Press
MIN
key, to change the minutes.
IV. Current time is now set.
Setting the Timer
Setting Timer 1.
I. Press
TIMER
key to change Timer 1 Start hours.
II. Press
HOURS
key, to change hours.
III. Press
MIN
key, to change the minutes.
IV. Press
TIMER
key again to toggle Timer 1 Finish.
V. Press
HOURS
key, to change hours.
VI. Press
MIN
key, to change the minutes.
Timer Default Settings
A new Hydrochlor® initially has been set with the following defaults timers:
SUMMER
Timer 1 START
8:00
Timer 1 FINISH
12:00
Timer 2 START
16:00
Timer 2 FINISH
20:00
WINTER
Timer 1 START
9:00
Timer 1 FINISH
11:00
Timer 2 START
17:00
Timer 2 FINISH
19:00
"MM UJNF TFUUJOHT DBO CF JOEJWJEVBMMZ QSPHSBNNFE IPXFWFS BMUFSJOH UIF UJNFT XJMM
automatically change the matching WINTER time to:
START Times
5JNFIS
END Times
5JNFIS
(Unless the START time is 23:xx hours or the FINISH time is 0:xx hours, in which case the WINTER
time will be set to the same as the [summer] time).
Therefore unless a particular set of WINTER times are required, there is no need to separately enter
them.
GAS TRAP
40/50mm glued
connections