Waterco 20 SC Owner's Manual - page 6
I pg 09
Waterco Hydrochlor®
TROUBLESHOOTING
SYMPTOM
POSSIBLE CAUSE
REMEDY
-PXDIMPSJOFMFWFMJOQPPM
Operating time too short
Increase operating time
Production control set too low
Set production higher
Low salt
Add required amount of salt
Pool chemistry not correct
Have water tested
6OJUEPFTOPUPQFSBUF
No electrical power
Hydrochlor® switch off
Connect power, check fuse,
switch on Hydrochlor®
Pump not connected
Connect pump
/PULFFQJOHUJNF
Time clock setting, power
outage and battery not
connected
Reset clock, connect battery
link, If battery is flat this will
require reset after blackout
Electrical fault
Return to distributor for repair
TECHNICAL SPECIFICATIONS
Model
*OQVU8BUU
(kW) max
0VUQVU
current DC
(A) max
Chlorine
Production
(g/hr)
.BY1PPM$BQBDJUZ -
Climate
5FNQFSBUF
5SPQJDBM
20 SC
290
20
20
80,000
48,000
25 SC
330
25
25
100,000
60,000
30 SC
380
30
30
120,000
72,000
Model
20 SC
25 SC
30 SC
1SJNBSZ*OQVU7PMUT'SFRVFODZ )[
Input Power (W)
290
330
380
.BYJNVN5PUBM$VSSFOU "
10
10
10
1VNQ0VUMFU.BYJNVN "
8
8
8
Cell Voltage (V)
6 - 8
6 - 8
6 - 8
Degree of Protection
IP23
IP23
IP23
Cell Housing dimensions
GENERAL SAFETY RULES
1) The equipment mentioned in this manual is specially designed for the sanitizing of water in
swimming pools.
2) It is designed to work with clean water at a temperature not exceeding 35°C (95°F).
3) The installation should be carried out in accordance to the safety instructions of swimming
pools especially Standard HD 384.7.702 and the specific instructions for each facility.
4) The rules enforced on accident prevention should be carefully followed.
5) Any modification of the chlorinator requires the prior consent of the manufacturer. Original
replacement parts and accessories authorized by the manufacturer ensure a high level of safety.
The manufacturer accepts no liability for the damage and injuries caused by unauthorized
replacement parts and accessories.
6) During operation, some parts of the chlorinator are subject to dangerous electric voltage.
Work may only be performed on the chlorinator or on the equipment connected to it after
disconnecting them and the starting device from the mains power.
7) The user should make sure that assembly and maintenance tasks are carried out by qualified
authorized persons and that these persons have first carefully read the Service and Installation
Instructions.
8) The operating safety of the chlorinator is only guaranteed if the Installation and Service
instructions are correctly followed.
9) The limit values stated in the Technical Specifications should not be exceeded under any
circumstance.
10) In the event of defective operation or fault, contact the manufacturer’s Technical Support
Department or its nearest Authorized Agent.
11) If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or
a similarly qualified person.
12) This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.
These chlorinators are approved and conformed to AS3136 Swimming Pool Equipment, as a
prescribed article under Australian Registration.
These chlorinators conform to the Australian Electromagnetic Compatibility Standard marked by
the C-tick.
WARRANTY
Two Years Warranty:
Hydrochlor® Chlorinator
ZFBSZFBSQSPSBUB
Titanium cell
ZFBSZFBSQSPSBUB
Power pack
2 years
Commercial Installations
1 year
*Please refer to Waterco’s Warranty terms and conditions
A (mm)
B (mm)
C (mm)
D (mm)
423.5
136.5