WaterLogic WL270 Service Manual - page 4
WL270 Manual
Page 15 – Revision 2‐2‐2017
HOT TANK DESCALING INSTRUCTIONS
The Hot Tank requires removal of mineral deposits (descaling) on a regular basis. Typically
descaling should take place every 6 to 12 months to preserve the long‐term health of your unit.
Use non‐toxic cleaner such as ScaleKleen, DEZCAL, 20% Citric Acid Solution, or Undiluted Vinegar
Solution to remove mineral deposits as directed by the manufacturer depending upon filtration
and local water conditions.
Descaling is an important process that removes calcium deposits, or scale, that can build up
inside a tank over time. Calcium and scale is non‐toxic but left unattended will hinder your unit’s
performance.
WARNING!
PERSONAL PROTECTIVE EQUIPMENT REQUIRED. Always ensure proper
ventilation and use rubber or nitrile gloves and eye protection when using chemicals. Refer to
Material Safety Data Sheet for specific requirements of each product.
CAUTION!
STAINLESS STEEL TANK DESCALING
.
The Hot Tank is made from stainless steel. Ensure descaling solution is compatible with
stainless and always flush the unit completely. Dispose in an environmentally safe manner.
Materials Needed:
Personal Protective Equipment. Rubber or Nitrile Safety Gloves and Protective Eyewear
Phillips Screwdriver
Temperature Gauge
Water Pitcher or Container to collect water from the faucet
5‐gallon container or drain basin
Citric Acid Based Cleaner
¼” Plastic Tubing, at least 4 feet in length, and assorted ¼” quick connect fittings
Sanitizing Cartridge
Food Coloring
1. Check to ensure that the Red Heater and Compressor Power Switch is the O=OFF
position.
NOTE:
Switches have internal LED that illuminates when placed in I=ON position.
2. Turn off the water supply and unplug the unit.
3. Remove top Cover
4. Remove Reservoir Lid
5. Remove Hot Tank Drain cap on back of unit and allow all water to drain from unit.