Watts Premier WP-2 BVC Installation, Operation And Maintenance Manual - page 12
Performance Data Sheet
Watts Premier Inc.
8716 W Ludlow Drive Suite #1
Peoria, AZ 85381 USA
WP-2 BVC
GENERAL USE CONDITIONS:
1: System has been independently tested for the removal of microbiologically contaminated water. The system is not intended
for the treatment of water that has an obvious contamination source, such as raw sewage. This system is not intended to
convert wastewater to microbiologically safe drinking water.
2: Operating Temperature:
Maximum 100
o
F (37.8
o
C)
Minimum 40
o
F (4.4
o
C)
3: Operating Water Pressure:
Maximum 85-psi (5.98 kg/cm
2
)
Minimum 20-psi
4: Maximum flow Rate:
0.50 gpm (1.89 lpm)
5: Rated Capacity:
2000 Gallons (7,500 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note: Depending on incoming feed water conditions replacement time frame may vary.
Description
Part Number
Change Time Frame
Cost
Stage 1: sediment: 5M-10
104017
6 Months
$ 3.50*
Stage 2: Microbiological Carbonblock
101003
6 Months
$33.95*
*All prices subject to change without notice
This system has been tested according to NSF/ANSI Standard 42 for the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as
specified in NSF/ANSI 42. Testing performed under standard laboratory conditions, actual performance may vary.
Contaminant
Influent Challenge Concentration
Percent Reduction Achieved
Chlorine Taste & Odor
2.0 mg/L + 10%
98%
Bacteria*
99.9999%
Virus*
99.99%
Cyst*
99.95%
* Independently tested and verified by BioVir Laboratories
These substances are not necessarily in your drinking water.
Refer to the owners manual for further maintenance requirements and warranty information. System must be maintained according to
manufacturers use instructions, including replacement of filter elements.
Questions? Contact Watts Premier 800-752-5582
www.premierH2o.com
480-675-7995
System has been tested by Bio Vir as a Microbiological
Water Purifiers based on the recommendations set forth in
the USEPA Guide Standard and Protocol for Microbiological
Water Purifiers (OPP Task Force Report, 1987).
12