Watts Premier WP-2 BVC Installation, Operation And Maintenance Manual - Installation
1 WP-2 Unit
2 Filters
1 Parts Bag
1 Faucet Assembly
If any of the items are missing, please contact Watts Premier prior to installing
Tools Recommended For Installation
A small knife
Variable speed drill
1/8” (3mm), 1/4” (6.4 mm) and 7/16” (11.0mm) drill bits
1/2” Diamond Tip Drill bit (for porcelain sinks)
1/2” hole punch (for stainless steel sinks)
1/2” and 5/8” open-end wrenches (or adjustable wrenches)
Phillips screwdriver
Contents of Under Counter System
Installation
This system has been designed to fit under most kitchen sinks. Please read the entire manual carefully
before proceeding with installation.
4
Step 1: Mounting System Under Sink
(A) Locate a space under the sink that
allows the unit to be mounted close
to the cold water supply and allows
for easy access during maintenance
and filter changes. System must
be installed to the cold water supply
only. Allow approximately 2” (5cm)
clearance between the bottom of the
filter housing and the floor of the sink
cabinet.
(B) Using the mounting holes on the
bracket, mark the location for the
mounting screws on the cabinet wall
under the sink.
(C) Screw the (2) screws into the wall at
the marked location.
(D) Hang the module on the screws using
the mounting holes in the bracket.
Installation needs to comply with state and local plumbing regulations.
Operational Parameters
Maximum
Minimum
Operational Temperature 100°F (37.8°C)
40°F (4.4°C)
Operating Pressure
85 psi (5.98 kg/cm²)
20 psi (1.406 kg/cm²)
pH Parameters
10
5
Flow Rate
0.5 GPM @ 60 psig
Sink
Green
Tubing
Blue
Tubing
HOT
COLD
Counter Top
Two Stage Under Counter (WP-2)