Air Top 3500 ST / Air Top 5000 ST
Technical data
69
Heater
Operation
Air Top 3500 (5000) ST B
Air Top 3500 (5000) ST D
Air Top 3500 ST D Volume Plus
Type test permit
e1*72/245*95/54*1221*00
e1*2001/56*0021*00
e1*2001/56*0020*00
Model
Air heater with evaporator burner
Heat output
Control range
1.8 – 3.5 kW
1.5 – 3.5 (5.0) kW
Fuel
Petrol
Diesel/PME
Fuel consumption
Control range
0.17 – 0.35 (0.52) kg/h
(0.19 – 0.46 (0.66) l/h)
0.19 – 0.35 (0.50) kg/h
(0.18 – 0.42 (0.60) l/h)
Rated voltage
12 V
12 V
24 V
Operating voltage range
10.5 - 16 V
10.5 - 16 V
21 -32 V
Rated power consumption
Control range
15 - 33 (95) W
Max. ambient temperature:
Heater:
- Operation
- Storage
Metering pump - Operation
- Storage
Control element- Operation
- Storage
-40... +40 °C
-40... +85 °C
-40... +20 °C
-40... +85 °C
-40... +75 °C
-40... +85 °C
Maximum combustion air inlet temperature
-40... +20 °C
Adjustment range for interior temperature
+5... +35 °C
Delivery rate for hot air
at fan speed
against 0.5 bar
max. 132 (200) m
3
/h
at 3600 (5000) rpm
CO
2
in exhaust gas
(permitted function range)
1.5 kW: 5.0-8.0 %
3.5/5.0 kW: 9.0-12.5 %
1.5 kW: 5.0-8.0 %
3.5/5.0 kW: 9.0-12.5 %
Heater dimensions
Length 423
± 2 mm
Width 148
± 1 mm
Height 162
± 1 mm
Weight
5.9 kg