Webasto Air Top Series Operating Instructions Manual - page 5
5
Duration
Duration allows for the selection of continuous heater
operation or timed operation (30 minutes – 14 hours in
30 minute increments).
IMPORTANT: Timed duration is not to be mistaken for
Timer functionality. The duration times above are used
when turning the heater on manually. I.e. set the heater
duration for 8 hours before heading to bed.
Note: If timed operation is selected 10 hours is default.
Continuous
LVD
LVD “Low Voltage Disconnect” allows the user to set
the battery voltage level at which the Webasto
SmarTemp Control 2.0 will shut down the heater.
If battery voltage is equal to or less than the threshold
selected +0.1v, the heater will not start. I.e. if an 11.5v
threshold is selected the heater cannot be started until
B+ has reached 11.7v.
12 volt - Range between 11v – 12.5v
24 volt - Range between 21v – 25.5v
11.4v
24.2v
Password
A password can be set to prevent access to the
advanced “Options” menu. Enter a 4 digit code
passcode to begin securing the “Options” menu.
Note: This is typically used in fleet vehicle applications.
OFF
PM Reminder
If the heater has not run 30 days, the preventive
maintenance (PM) reminder will alert the operator with
a message to run the heater for 20 minutes. The
indicator lights will flash red as a visual reminder.
The operator will have the ability to Start the 20 minute
maintenance cycle or delay it via a “Snooze” option.
When Snooze is selected the PM reminder will postpone
until 12:00PM the following day.
ON
Time & Date
Set time and date using the rotary knob and selection
button. 12 (AM / PM) or 24 hour available.
The Webasto button can be used to go back to the
previous field if additional changes are needed.
12 hour