Webasto ALTOX WBUS-4 Owner's Manual - 2. Setup (Sms Commands)
2. Setup (SMS commands)
To manage send SMS command to SIM-card number of the module.
Possible to setup several settings at same time separated by commas.
Adjustable parameters
Text message
1, 2. Request SMS with settings 1/2
settings1 / settings2
3. Switch on the heater
heater_on (or start)
4. Switch off the heater
heater_off (or stop)
5. Request the heater status
heater_status
6. Read Webasto heater errors
heater_read
7. Erase Webasto heater errors
heater_erase
8, 9. Unlock Webasto T5GP
(Т5)
heater_unlock1 (2)
10. WBUS-auto/TTC/TTV/+12V/1533/t1/t2/vent./w heater_type0/1/.../8
11. Stop heater when errors WBUS
rstop0 / rstop1
12. Interfacing with other controls
bind0 / bind1
13. Button type: fixed-type button / not fixed
key0 / key1
14. Heater time range (from 10 to 55 min)
time1:30
15. Delay before is ON OUT (1–20 min)
time2:0
16. Delay before is OFF OUT (1–10min)
time3:0
17. Voice menu (OFF / ON)
voice0 / voice1
18. SMS confirmation about ON/OFF heater
setsms0 / setsms1
19. SMS about heater work errors (OFF/ON)
errorsms0 / errorsms1
20. Temperature control (OFF/ON)
temp0 / temp1
21. The upper temperature limit (70 – 110°
С)
temp_high:85
22. The lower temperature limit (10 – 80°C)
temp_low:60
23. Save the tel. number
Х (where Х=1, 2, 3)
num
Х:+37529xxxxxxx
24. Save the balance number
bal:*100#
25. To make USSD-request
ussd:*110*4*1#
26. Access point (APN)
apn1:mts
27. User name
apn2:mts
28. Password
apn3:mts
29. IP server address
server1:123.123.123.123
30. Server port
server2:12345
31, 32. frequency at work time and ping, sec.
freq1:10 and freq2:60
33, 34. Quantity tries of setup GPRS and TCP
count1:5 and count2:3
35. Password setup before enter SMS commands
pass:1234
- After Webasto unlocked, disconnect power supply and then erase the errors.
- To delete setup/number send a command without parameters (e.g. num1:).
Sample outgoing SMS with setup 1:
H0 R1 B0 K1 V1
- setup: type WBUS, rstop1, bind0, key1, voice1
S0 E1 T:30,0,0
- setsms0, errorsms1; meaning: time1, time2 and time3
Temp: 60
С-85С
- temperature control from temp_low to temp_high
N1, N2, N3, B
- tel. numbers and number of request balance account
P:"" (up to 4symb.) - if any/no any password for SMS commands