Webasto ALTOX WBUS-4 Owner's Manual - 3. Technical Data
Sample outgoing SMS with ID and setup 2:
ID:123456789012345
- unique ID device
S:"123.123.123.123","12345" - IP server address and port
G:"mts","mts","mts"
- APN point , user name, password
F:10,60,10,5
- setup freq1, freq2, count1, count2
Sample outgoing SMS status message:
Webasto OFF
- heater status
Signal GSM (0-31): 28
- GSM network signal level
Voltage: 12.8V
- voltage vehicle electrical system
Temperature: 0
С
- value of the Webasto temperature sensor
Flame: no
- state of the Webasto flame sensor
3. Technical data
Parameter
Range
Power supply voltage
10V – 16V
Current consumption in the standby mode
less
20мА
Maximum current of additional output
50
0мА
+12V (through fuse 1A)
GND (common)
IN KEY
WBUS
OUT
Leds are in
SIM-card slot
SIM-card
1. Make installation of the devise as far as possible from metal parts and
wire harnesses.
2. Before insert a SIM-card set to off PIN-code request.
3. In KEY connected to external control, to fixing or not fixing button
(waiting for a +12V).
4. Output OUT commutes +12V. Intended for heater control by analog
signal, for connecting LED, coolant pump or interior heater fan.
Switched on with delay "time2" after Webasto is on, switched off with
delay "time3" after the heater finished its work.
5. The red led duplicates the output status "OUT".
6. The led "NET" has orange color.