Connecting to the monitor
Check resolution of monitor before connection.
When using HDMI Port : 1920 x 1080p ( HDMI v1.2 Standard )
Make sure to use a camera supporting HD-SDI standard.
We stongly recommend to use HDMI certified cable when connecting DVR output to HDMI monitor
Connecting camera
Connect HD-SDI camera to DVR using recommended coaxial cable.
Connected camera’s resolution(1080p or 720p) is automatically recognized by DVR when DVR is booting.
Please be careful that same resolution cameras should be connected to a DVR. You cannot mix cameras which
have different resolution.
Recommended cable
5C-FB(T), 5C-HFB(T), L-5CFB
L-4.5CHD, L-6CHD : HD-SDI customized cable
Recoding Setting
[Continuous&Event Record] [Manual&Event Record]
Continuous & Event
The continuous recording will perform automatically under the Continuous & Event configured value after the
DVR booted.
Manual & Event
Manual record can be configured in “Program” of record menu and Manual / Event record is
available to Start/Stop with pressing [REC] button on front panel.
In case of Manual Setting, user needs to check recording indicate status on the front panel. If there are no
recording indicate please press REC button to start recording.
Cable type
HD-SDI transmission
distance
Remark
5C2V
about 100M
Cable for analog signal
4C-FB(T), 4C-HFB(T), RG59
about 150M
High-foamed cable, double or trishield
recommended
5C-FB(T), 5C-HFB(T), L-6CHD, RG6
about 200M
Customized for HD-SDI
Menu Record Record