Wechillit EF SERIES 1-TANK Manual - Warning!
●
Do not use a power supply with incorrect voltage.
Do not use a main switch that does not comply with safety regulations.
●
In thunderstorm conditions, unplug the unit to avoid damage from
power surges.
●
Take care not to damage the unit with hard objects.
●
After using, please shut off main switch.
●
The installation and maintenance of electric circuit must be carried out
by professionals.
●
If the power cord is damaged, the user should consult the manufacturer,
maintenance department or professionals to repair.
Warning!
●
When using ensure that your hands, plug and switch are dry.
●
Oil should not be allowed to get lower than the minimum oil level. Do not dry
burn.
●
Do not use water to clean the electric box directly or immerse the electric box into
water to clean.
●
Do not use old oil to fry because it will cause over boiling.
G. Troubleshooting
Problem
Cause
Solution
1. When the machine is
plugged in and the power is
switched
on,
the
power
indicator does not illuminate
and there is no heat.
1. The plug is not properly
inserted.
2. Micro-switch
contacts
may not be correctly
seated.
1. Ensure the plug is inserted
properly.
2. Adjust the limit distance of
micro-switch
2. The heating indicator does
not
illuminate
and
temperature does not rise.
1.
The
connection
of
electric element is loose.
1. Tighten the screws on both
sides of the element.
2. Replace the element.
3. Power indicator is on but
the setting temperature is not
raised.
1.Temperature controller is
burned.
1. Change temperature controller.
4. Temperature control is
normal but indicator is not
1. Indicator is burned.
1. Change indicator.