Xenotronix/TLI HPX60 Series User Manual - page 11
OPTIMIZER
TM
SX150-1
User’s
Manual
Xenotronix/TLI
8
BATTERY CHARGER SPECIFICATIONS
General Conditions
Ambient Temperature = 25ºC (77ºF)
Operating Temperature
0 to 50ºC (32 to 122ºF)
Storage Temperature
-40 to 80ºC (-40 to 176ºF)
Input Power Requirements
110-127 VAC, 50-60Hz, 2A
Maximum Charge Current
12.5 A
Absorption Charge Voltage
14.70 Vdc (AGM) 14.10 Vdc (GEL)
Float Charge Voltage
13.62 Vdc (AGM) 13.50 Vdc (GEL)
Condition / Equalize Current
approx. 1.25 A
Equalize Charge Voltage
15.60 Vdc
Battery
12-Volts,
Sealed
Lead-Acid
Input Cable
3/18 AWG, 6’ long with NEMA 5-15P plug
Output Cable
2/14 AWG, 6’ long with polarized connector,
(harness with 6mm (1/4”) ring terminals included)
Enclosure
extruded aluminum heat sinking chassis
Indicators
yellow LED = Charge; green LED = Ready
Dimensions (L x W x H)
8.50” (21.6 cm) x 6.40” (16.3 cm) x 2.00” (5.1 cm)
Weight (including cables)
3.45 lbs (1.57 kg)
DIMENSIONS
4.00
8.50
6.00
6.40
2.00