7-4
Environmental
conditions
Operating environment
Temperature: 20°C to 32°C (68°F to 90°F)
Humidity: 40% to 60%, No condensation
Printing accuracy coverage
Temperature: 22°C to 30°C (72°F to 86°F)
Humidity: 40% to 60%, No condensation
Rate of change
Temperature: within 2°C (3.6°F) per one hour
Humidity: within 5% per one hour
Archiving environment
(Ink unfilled)
Temperature: –20°C to 60°C (-4°F to 140°F)
Humidity: 20% to 80%, No condensation
Storage life: six months
Archiving environment
(Ink filled)
Temperature: -10°C to 40°C (14°F to 104°F)
Humidity: 20% to 80%, No condensation
Storage life: four days at 32°C (90°F) or higher
Power
Power voltage
AC 90V to AC 132V / AC 198V to AC 264V
Frequency
50Hz/60Hz ± 1Hz
Power consumption
Printing
1260W (Heater ON)
Standby
40W or less (when the idle heat is turned OFF)
Outer dimensions
Height
1218mm (49") (including the stand)
Width
1,875mm (75")
Depth
685mm (27")
Weight
Printer
58.0kg (127.6lbs.)
Stand
21.3kg (46.9lbs.)
Total
79.3kg (174.5lbs.)
Item
Specification