    Dx100r (93005aw) dx100s (93025aw) dx100tr (93006aw) dx100ts (93026aw) dx100pr (93007aw) dx100ps (93027aw) dx100htr (93008aw) dx100hts (93028aw) xpelair simply silent dx100 ™ installation and maintenance instructions english nederlands ُ ِ ََ dx100hptr (93009aw) dx100hpts (93029aw) dx100pirr (93010aw...

  • Page 2: English

    • do read the entire instruction leaflet before commencing installation. • do install each fan with a means for disconnection in all poles in the fixed wiring. • do make sure the mains supply is switched off before attempting to make electrical connections or carry out any maintenance or cleaning. •...

  • Page 3: This Appliance Can Be Used

    This appliance is intended for connection to fixed wiring. Check that the electrical rating shown on each fan matches the mains supply. The appliance is double insulated and does not require an earth connection. All installations must be supervised by a qualified electrician. Installations and wirin...

  • Page 4: Overall Dimensions (Mm)

    Overall dimensions (mm) back plate fixing positions a b front cover removal c d depress cover latch with tool & remove cover complete english 3.0 2.0 1.0 0 1.0 2.0 3.0 1.0 2.0 3.0 4.0 5.0 6.0 (m) 1.0 2.0 3.0 4.0 5.0 6.0 (m) (m) (m) 90˚ 60˚ 4.0 3.0 2.0 1.0 0 horizontal detection area 3.0 2.0 1.0 0 1....

  • Page 5: Wiring and Setting Up

    Wiring and setting up g1 see detail a dx100r / dx100s dx11pr/dx100ps dx100tr / dx100ts customer connection terminal english important – please read adjusting the humidity setting adjusting the run on timer setting fan switches on at lower level of condensation (anti-clockwise) more sentitive (rh = 5...

  • Page 6: Wiring and Setting Up

    Wiring and setting up g2 g3 dx100htr / dx100hts dx100hptr / dx100hpts dx100pirr / dx100pirs customer connection terminal english see detail g see detail f customer connection terminal customer connection terminal detail g scale 2.000 set jumper to required position for speed setting low speed high s...

  • Page 7: English

    English if wall mounting the fan, you will also need: • a 100mm diameter prepared hole. • an appropriate external wall grille and Ø100mm wall sleeve duct (supplied). Cut ducting to correct length if required. The wall tube supplied is telescopic and can be extended to 300mm maximum. If ceiling mount...

  • Page 8: English

    10. Insert the fan tube into the wall duct/ceiling as before. 11. Fasten the back-plate to the wall/ceiling using appropriate fasteners supplied. See figure a. 12. If using screws, do not over tighten. Mount the back draft shutter 13. Peel the backing from the foam strip supplied and attach it aroun...

  • Page 9: English

    English fan settings speed setting the fans are factory set to low speed, but have two speed settings for different applications. Select either high or low speed by connecting the jumper between the centre and high or low speed pin on the jumper (see figure g). Dx100tr / dx100ts / dx100pirr / dx100p...

  • Page 10: English

    English cleaning (recommended once a month) 1. Before cleaning, isolate the fan completely from the mains supply. 2. Remove the front cover by depressing the latch on the underside of the cover and pulling off the front cover from the bottom. 3. To clean the front cover, either wipe it with a damp, ...

  • Page 11