Yaesu G-550 Instruction Manual - page 5
P
AGE
3
G-550 I
NSTALLATION
M
ANUAL
CONTROL CABLE PREPARATION & CONNECTION
1. Assemble the cable according to the following diagrams.
2. Connect each wire to the terminal on the rear panel of the controller, making sure
to match the numbers on the pins (terminals 7 and 8 are not used), and insert the
connector to the Jack on the rotator.
3. On the controller, make sure that the POWER switch is in the “OFF” position,
and connect the line cord to the AC power outlet.
4. Turn on the POWER switch. The meter lamp should light and the meter indicate
approximately 90° (center).
5. Press the UP switch. The rotator should turn as the meter indication moves to the
right. Release the UP switch and confirm that the rotator slowly stops.
6. Repeat step 5, pressing the DOWN switch instead of the UP switch. The rotator
should turn in the opposite direction as the meter indication moves to the left.
7. If operation does not occur as described above, check for a wiring error in the
cable connections. When everything checks out in the above steps, slide the water
resist cap over the connecter on the rotator. Remove the cable clamps from the
controller, clip them over the cables, and screw them back onto the controller.
Then replace the terminal cover.
Notes on Controller Operation:
H If both UP and DOWN switches are pressed at the same time, the rotator turns
clockwise (up).
H Remember to turn the controller off when the rotator is not in use.
Make sure to insert the
Water Resist Cap first.
Tin the wire with solder.
Terminal 7 is not used.