Yale ENA-PIR Instruction Manual - page 2
Programming
Step 1: Remove the PIR battery insulator
on the back. It will take 30 seconds for the
PIR to initalise (with LED flashing). To allow
calibration, stay away from the detection lens
during this period.
Step 2: Login to the engineer menu on the
control panel. Select “Zone Settings” → “Zone
Config.” → “Add Zone” on the menu. Press OK
and the LCD of the Control Panel will display
“*Push button on* Device to add”.
Step 3: Press PIR’s Learn button.
Step 4: Then if the Control Panel detects a
signal transmitted from PIR, the Control Panel
will display
“Detected (OK?) PIR sensor”. Press OK to
confirm the learning.
Step 5: Refer to the operation manual (section
“Add Zone”) of your Control Panel to complete
the learn-in parameter setup.
Step 6: To find the best installation location for
the PIR, you will need to make a “Walk Test”.
Press the “Return” button and go back to the
root selection. Select the “Testing” Menu, then
select the “Walk Test” option.
Step 7: Hold the PIR in the desired location
and press the test/learn button. The RSSI signal
strength value will be displayed on the control
panel, varied from 0 ~ 9 (9 indicates the best
signal strength performance). It is suitable for
installation if the RSSI value is 5 or greater.
Device is now ready for mounting.
Mounting
The PIR is suitable for surface or corner
mounting. There are knockout holes in the
base cover to allow fixing. Using the holes as a
template to drill mounting points on the wall.
Insert wall plugs and fix the base onto the wall.
Put the front cover on the PIR to complete the
mounting process.
It is recommended to install the PIR in the
following locations:
• Inapositionsuchthatanintruderwould
normally move “across” the PIR’s field of
view.
• Between1.9~2.0Mabovegroundforbest
performance.
• Inacornertogivethewidestview.
• Whereitsfieldofviewwillnotbeobstructed
e.g. by curtains, ornaments etc.
Limitations
• DonotpositionaPIRtolookdirectlyat
a door protected by a Door Contact. This
may cause the Door Contact and the
PIR to transmit at the same
time and cancel each other out.
• DonotexposePIRtodirectsunlight.
• AvoidinstallingthePIRinareaswhere
there are rapid change of temperature, i.e.
air conditioner, heaters, etc.
• Avoidlargeobstaclesinthedetection
area.
• Notpointingdirectlyatsourcesof
heat e.g. fires or boilers, and not above
radiators.
• Avoidmovingobjectsinthedetectionarea
i.e. curtain, wall hanging etc.
2M
0 1 2 3 4 5 6 7 8 9 10 11 12 13