Mounting using screws and wall plugs
1 Loosen the bottom screw
and open the door/
window contact.
2 Knock out the holes on the
base as shown.
3 Drill holes into the
mounting surface using
the holes in the knockouts
on the base as template.
4 Fit wall plugs (if required) and secure with the
screws provided.
5 Fit sensor back together and tighten screw.
6 Test sensor by pressing the test button and
opening and closing the door/window. The LED
should light when the door/window is opened.
Installation is complete.
Mounting the Help button
1 Break through the knockouts (where the plastic is
thinner).
2 Using the holes as a template, drill holes in the
surface and insert wall plugs if fixing into plaster or
brick. Screw the rear case to the wall.
3 Replace the cover and tighten the screw.
Mounting the Smoke Detector
1 The base has two mounting slots. Using the slots
as a template, drill holes and insert the wall plugs if
fixing to plaster. Screw the rear case to the ceiling
using the screws provided.
2 Replace the cover.
Mounting the Door Contact
Frame
Door/Window
Gap no more
than 8mm
Magnet
Sensor
1 Find a location where the Door/window contact
is to be mounted. It should be mounted between
the door/window frame and the door/window as
shown at the top of the opening. The magnet is to
go on the door/window while the sensor is to be
placed on the frame. The gap between the magnet
and sensor should be no more than 8mm when
closed. Windows can be protected in a similar way
to doors. Make sure the tamper switch spring is
fully depressed.
2 Perform a radio range test by pressing Test/Learn
Button on the door/window sensor while the
control unit is in walk test. This indicates the
device is within range. If this step fails please find
an alternative location.
Mounting using adhesive pads
1 Clean the mounting surface with a suitable
degreaser agent.
2 Remove the protective film from one side of the
adhesive pad and apply to the back of the sensor
and magnet
3 Remove the remaining protective film and firmly
press into place.
4 Test sensor by pressing the test button and
opening and closing the door/window. The LED
should light when the door/window is opened.
Installation is complete.
Knockouts