Yale HSA 6300 Manual - page 5
5
!
!
Keyfob remote control accessory
Can be used inside or outside the property and
can be kept on your keyring.
Smoke detector
• Mount in the middle of the ceiling at the top of
a stairwell, or on the centre of hallway ceilings
where smoke would most likely be detected.
• Do not mount in corners or above cooking
appliances and heaters.
• Install additional detectors if there are closed
doors preventing smoke from reaching
detectors.
Door/Window contact
Select a door that will be the main point of entry
and exit, usually your front door.
• Mount as high as possible
• Do not aim a PIR at this door or window
!
!
PIR movement detector
• Mount in a position such that an intruder would
normally move across the PIRs field of view.
• Height should be between 1.7 and 2.3 metres
above floor level.
• Location in a corner will ensure wider room
coverage.
• Do not mount the PIR where its field of view will
be obstructed e.g. by curtains, ornaments etc.
• Do not point directly at sources of heat e.g. fires
or boilers, and do not position directly above
radiators.
• Avoid mounting the PIR directly facing a
window.
• Do not point the PIR at a door protected by a
door/window contact.
Control unit
• Ensure the control unit is accessible when
entering through a protected entry/exit point.
• Avoid mounting the control unit where it would
be visible from the outside of the premises
• Locate by a mains socket and telephone point.
Siren
Choose a position on an external wall where the
siren would be most prominent. Mount as high as
possible, out of easy reach.