Yamaha PLG100-VL Owner's Manual - Midi Data Format
41
Address
Size
Data
Parameter
Description
Default
(H)
(H)
(H)
value(H)
09 0p 00
1
00 - 01
NOTE ASSIGN
OFF/ON
01
01
1
NOT USED
--
02
1
NOT USED
--
03
1
00 - 62
PRESSURE CONTROL NO.
off - 95, AT, VELOCITY, PB
00
04
1
00 - 7F
DEPTH
-64 - +63
40
05
1
00 - 62
EMBOUCHURE CONTROL NO.
off - 95, AT, VELOCITY, PB
00
06
1
00 - 7F
DEPTH
-64 - +63
40
07
1
00 - 62
TONGUING CONTROL NO. off - 95, AT, VELOCITY, PB
00
08
1
00 - 7F
DEPTH
-64 - +63
40
09
1
00 - 62
SCREAM CONTROL NO.
off - 95, AT, VELOCITY, PB
00
0A
1
00 - 7F
DEPTH
-64 - +63
40
0B
1
00 - 62
BREATH NOISE CONTROL NO.
off - 95, AT, VELOCITY, PB
00
0C
1
00 - 7F
DEPTH
-64 - +63
40
0D
1
00 - 62
GROWL CONTROL NO.
off - 95, AT, VELOCITY, PB
00
0E
1
00 - 7F
DEPTH
-64 - +63
40
0F
1
00 - 62
THROAT FORMANT CONTROL NO. off - 95, AT, VELOCITY, PB
00
10
1
00 - 7F
DEPTH
-64 - +63
40
11
1
00 - 62
HARMONIC ENHANCER CONTROL NO. off - 95, AT, VELOCITY, PB
00
12
1
00 - 7F
DEPTH
-64 - +63
40
13
1
00 - 62
DAMPING CONTROL NO.
off - 95, AT, VELOCITY, PB
00
14
1
00 - 7F
DEPTH
-64 - +63
40
15
1
00 - 62
ABSORPTION CONTROL NO.
off - 95, AT, VELOCITY, PB
00
16
1
00 - 7F
DEPTH
-64 - +63
40
TOTAL SIZE 17
* p = Part Number
VL Part Parameters Address Size Data Parameter Description Default (H) (H) (H) value(H) 09 00 17 1 00 - 7F AMP LEVEL SCALE BREAK POINT C-2 - G8 3C 18 1 00 - 7F DEPTH -64 - +63 40 19 1 00 - 7F FILTER CUTOFF SCALE BREAK POINT C-2 - G8 3C 1A 1 00 - 7F DEPTH -64 - +63 40 1B 1 NOT USED -- 1C 1 NOT USED -- TOTAL SIZE 06 MIDI Parameter Change (VL Part Assign) Address Size Data Parameter Description Default (H) (H) (H) value(H) 70 00 ss 1 00 - 0F, 7F Part Assign A 1.....A 16, off 0 TOTAL SIZE 01 * ss = Serial Number for PLG100-VL
MIDI Data Format