Z-Wave DCH-Z310 Manual - page 5
5
If a 20-foot distance is not possible, e.g. in a mobile home, try to install
the alarm as far away from the combustion particles as possible,
preferably on the wall. To prevent nuisance alarm alarms, provide good
ventilation in such places.
*
In very dusty or dirty areas, dirt and dust can build up on the
alarm’s sensing chamber, to make it overly sensitive. Additionally, dust
or dirt can block openings to the sensing chamber and keep the alarm
from sensing smoke.
*
Near fluorescent lights, electrical “noise” from fluorescent lights may
cause nuisance alarms. Install Smoke Sensor at least 5 feet(1.5 meters)
from such lights.
Installation
1.
At the place where you are going to install your Smoke Sensor,
draw a horizontal line six inches long.
2.
Remove the mounting bracket from your device by rotating it
counterclockwise.
3.
Place the bracket so that the two longest hold slots are aligned
on the line. In each of keyhole slots, drawing a mark to locate a
mounting plug and screw.
4.
Remove the bracket.
5.
Drill two holes at the marks and insert plastic wall plugs. Put the
Smoke Sensor away from plastic dust.
6.
Attach the bracket to the wall. Line up the slots of the bracket
and the Smoke Sensor. Push the sensor onto the mounting
bracket on turn it clockwise to fix it into the place. Pull onward
on the Smoke Sensor to make sure it is securely attached to the
mounting bracket.
Z-Wave Supported Command Class
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_SENSOR_BINARY_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_POWERLEVEL
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_SECURITY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Z-Wave Configuration Settings
Notice:
* All of the configuration, the data size is 1.
* The configuration marked with star(*), means after the remove the
setting still keep, don't reset to factory default. Unless the user execute
the “RESET” procedure.
* The reserve bit or not supported bit is allowed any value, but no effect.
NO.
Name
Def.
Valid
value
Description
7(*)
Customer
Function
4
All
Customer function switch, using
bit control.
0
Bit0
: Reserve.
0
Bit1
:
Reserve.
Mounting
bracket
Test / Silence Button
&
Power / Smoke Alarm LED
indicator