Z-Wave DCH-Z310 Manual - page 6
6
1
Bit2
:
Reserve.
0
Bit3
:
Reserve.
0
Bit4
:
Notification Type,
0: Using Notification Report.
1: Using Sensor Binary Report.
0
Bit5
:
Reserve.
0
Bit6
:
Reserve.
0
Bit7
:
Reserve.
10
Auto Report
Battery
Time
12
0~127
The interval time for auto report
the battery level.
0 means turn off auto report
battery. Each tick means 30
minutes. The default value is
12(6 hours).
Specifications
Power by CR123A lithium battery.
Signal (Frequency):
868.40 MHz, 869.85 MHz(EU),
908.40 MHz, 916.00 MHz(US),
922~927 MHz(JP/TW),
921.40 MHz, 919.80 MHz(ANZ),
869.00 MHz(RU),
865.20 MHz(IN),
916.00 MHz(IL),
Range:
Minimum 30 meters indoor,
70 meters outdoor line of sight.
Operating Temperature: 0
o
C ~ 40
o
C
For indoor use only.
Specifications subject to change without notice due to continuing
product improvement.
FCC ID: KA2CHZ310A1