Z-Wave ST814 Owner's Manual

Summary of ST814

  • Page 1

    1 st814 temperature/humidity detector the temperature/humidity detector is a z-wave tm enabled device which is fully compatible with any z-wave tm enabled network. Z-wave tm enabled devices displaying the z-wave tm logo can also be used with it regardless of the manufacturer, and ours can also be us...

  • Page 2

    2 2 3 4 1 5 function description led indication 1. Have z-wave controller entered exclusion mode. 2. Pressing key 3 times within 1.5 seconds will enter exclusion mode flashes exclusion node id has been excluded the rf reading displays 00 (mode 7) 1. Pressing key 3 times within 1.5 seconds will enter...

  • Page 3

    3 note: after removing batteries, please wait for 5 seconds before replacing them. Operation there are 8 modes available for selection. Press to select desired mode for different settings. Mode function 1 current temperature display (°c/°f) 2 current humidity display (%) 3 setting for temperature tr...

  • Page 4

    4 1.3 temperature trigger-off press and select mode 4 to enter setting of temperature trigger-off. Icon flashes and the screen shows the recorded trigger-off temperature. If no value is preset, the screen will display “ - - -。c ”. To adjust trigger-off value, press and hold for 5 seconds until a lon...

  • Page 5

    5 note: the humidity of trigger-on and trigger-off cannot be set equal; there must be at least 5% difference in between. For example, if now the trigger-on humidity is already set to be 50%, so trigger-off humidity can only be 45% ≦ or ≧55%. (values between 45% and 55% cannot be set.) once the detec...

  • Page 6

    6 sensor_multilevel_report [command class sensor multilevel, sensor multilevel report, sensor type = 0 x 01 (air temperature), precision+scale+size = 0 x 2a, sensor value 1 = (high byte of temperature value), sensor value 2 = (low byte of temperature value)] 1-1-3 low battery report when the battery...

  • Page 7

    7 2-1 auto report 2-1-1 time interval the temp./humid. Detector can be set to emit report of current status to the nodes of grouping 1 automatically at a set time. The time interval can be set from 1 minute to 24 hours. For instance, if time interval is set in 1 minute, the detector will report its ...

  • Page 8

    8 specifications operating frequency 868.42mhz (st814-1) / 908.42mhz (st814-2) operating temperature range -10℃ ~ 50℃ relative humidity range 20% ~ 90% temperature unit ℃ / ℉ battery type 1.5v x 3 alkaline/aa type battery operating range up to 30 meters line of sight (indoor) zdk version v5.02 *spec...