Z-Wave ZME_KFOB Manual - page 3
Once the controller is turned into inclusion mode turn the KFOB into management mode and hit Button 3. The
device is excluded by entering management mode and hitting button 3 when the controller is in exclusion mode.
To include/exclude the device in the NWI mode turn the KFOB into management mode and hit Button 1.
Operating the device
Depending on the button mode and operating modes configured using the configuration parameters the key fob
can be used in different ways.
Button modes:
Control is done with two buttons (This is the mode set on default) One group (No. 1) of devices is controlled by
button 1 and 3, the other group (No. 3) is controlled by button 2 and 4. Clicking the larger button turned on the
loads. clicking the smaller button turns off the loads. In case dimmers are controlled, holding down the larger
button will dim up, holding down the smaller button will dim down the load. Releasing the button will stop the
dimming function.
Control is done with two buttons and double clicks This mode is same as previous, but double clicks (on/off) or
click-holds (dimming) are used to control two more groups: No. 2 and No. 4.
Control is done with single buttons In this mode a group of device is controlled by a single button: single click
turns on, double click turns off devices in the group. In case dimmers are controlled, holding down the button
will dim up, click and hold down will dim down the load. Group number corresponds to the button label.
Operating modes:
Direct Control of associated devices with On/Off/Dim commands (This is the mode set on default). Devices are
controlled using Basic Set On/Off commands and SwitchMultilevel Dim Start/Stop. This mode implements
communication pattern 7.
Direct Control of associated devices with only On/Off commands. Devices are controlled using only Basic Set
On/Off commands. On dimming Up event On is sent, on dimming Down Off is sent. This mode also implements
communication pattern 7.
Switch All commands In this mode a all neighbouring devices will receive SwitchAll Set On/Off command and
interpret it according to their membership in SwitchAll groups. This mode implements communication pattern 7.
Direct Control of Devices in proximity Basic Set and SwitchMultilevel Dim commands are sent to a device in
proximity (50...100 cm) from the Fob. Attention: In case there are more than one Z-Wave devices nearby all these
devices may be switched. For this reason the proximity function should be handled with care. This mode
implements communication pattern 7.
Direct Activation of preconfigured scenes Associated devices in an association group are controlled by individual
commands defines by Z-Wave command class ‘Scene Controller Configuration’. This mode enhances mode Direct
Control of associated devices with On/Off/Dim commands and implements communication patterns 6 and 7.
Scene Activation in IP Gateway If configured correctly the buttons can trigger a scene in a gateway. The scene
number triggered is a combination of the group number and the action performed on the button and has always
two digits. The group number defines the upper digit of the scene number, the action the lower digit. The
following actions are possible:
1 = On
2 = Off
3 = Dim Up Start
4 = Dim Down Start