is (10 * group + ActionID), where ActionID is: 1 = On, 2 = Off, 3 = Dim Up Start, 4 = Dim Down Start, 5 = Dim Up
Stop, 6 = Dim Down Stop
Value
Description
0
Disabled
1
Switch On/Off and Dim (send Basic Set and Switch Multilevel) (Default)
2
Switch On/Off only (send Basic Set)
3
Switch All
4
Send Scenes
5
Send Preconfigured Scenes
6
Control devices in proximity
Typical click timeout (Parameter Number 20, Parameter Size 1)
Typical time used to differenciate click, hold and double clicks
Value
Description
1 — 100
in 10ms units (Default 50)
Send the following Switch All commands (Parameter Number 21, Parameter Size 1)
Value
Description
1
Switch off only (Default)
2
Switch on only
255
Switch all on and off
Invert buttons (Parameter Number 22, Parameter Size 1)
Value
Description
0
No (Default)
1
Yes
LED confirmation mode (Parameter Number 24, Parameter Size 1)
This allows to save battery
Value
Description
0
No confirmations
1
Confirm button press
2
Confirm button press and delivery (Default)
Send unsolicited Battery Report on Wake Up (Parameter Number 30, Parameter Size 1)