Z-Wave ZME WCS1 User manual - page 6
Enhanced Scene Activation:
In this mode every button action can issue a scene activation command with a dedicated number. The
scene number is a combination of the group number and the action performed on the button and has always
two digits. The group number defines the upper digit of the scene number, the action the lower digit. The
following actions are possible:
1 = On
2 = Off
3 = Dim Up Start
4 = Dim Down Start
5 = Dim Up Stop
6 = Dim Down Stop
Example: Clicking/double clicking the button 1 will issue a scene activation command for scene 11 (button 1
click, event on) and scene 12 (button double click 1, event off, single button control is used in this example).
This mode implements the communication pattern 6.
Child Protection
The device can be turn into a child protection mode. In this mode all local operation is disabled.
The device can be turned into a child protection mode. In this mode all local operation is disabled. The child
protection mode MUST be turned on wirelessly. However, in protected by sequence mode it is possible to
unlock the device for local operation by pressing any button for 5 seconds. The unlock state will last for 5
seconds.
Wakeup Intervals - how to communicate with the device?
W
This device is battery operated and turned into deep sleep state most of the time to save battery
life time. Communication with the device is limited. In order to communicate with the device, a static
controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices
and store commands that can not be received during deep sleep state. Without such a controller,
communication may become impossible and/or the battery life time is significantly decreased.
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6